Workshop 7: Forced and natural convection
Attempt these problems before opening the worked solutions.
1 Water cooling a reactor tube
Section titled “1 Water cooling a reactor tube”Uniform heat flux
Section titled “Uniform heat flux”Water at enters a 2.54 cm ID tube that is used to cool a nuclear reactor. The water flow rate is 0.114 . Using the Colburn analogy, determine the total rate of heat transfer, the exiting water temperature and the wall temperature at the exit, if the length of the tube is 4.5 m and the wall condition is one of uniform heat flux of 5.7 × .
Worked solution
Data
| Quantity | Symbol | Value |
|---|---|---|
| Tube diameter and length | ||
| Volume flow | ||
| Inlet temperature | ||
| Uniform wall flux |
| Water property | Constant value |
|---|---|
| Density | |
| Specific heat | |
| Dynamic viscosity | |
| Prandtl number |
Assumptions
Use the source solution’s rounded water properties throughout. Assume steady single-phase flow, fully developed turbulent heat transfer, negligible axial conduction and no heat loss elsewhere. Ignore entrance effects. The prescribed heat flux acts on the inner wetted surface.
Calculations
For this smooth tube use
Here is the Fanning friction factor, one quarter of the Darcy factor. The correlation applies to smooth turbulent flow in the approximate range . Use
and the local wall relation .
The imposed heat flux fixes the duty before a convection coefficient is needed.
The supplied flux is in kJ per hour per square metre. Convert energy and time together:
The wetted area is , hence
The flow rate is and .
The bulk energy balance gives
The cross-sectional area gives , and .
This is turbulent and within the stated smooth-tube correlation range.
Equation Eq. 1 gives
The wall is hotter than the local bulk water, as required for inward heat transfer.
The source’s chart estimate gives a slightly different coefficient.
The supplied smooth-tube formula removes chart-reading ambiguity.
Answer
The water receives , exits at , and has an exit wall temperature of .
The water temperatures retain two decimal places to show the small temperature rise.
2 Oil in a cold lake
Section titled “2 Oil in a cold lake”Thermally developing laminar flow
Section titled “Thermally developing laminar flow”Consider the flow of oil in a 30 cm diameter pipeline at an average velocity of 2 m/s and temperature of . A section of the pipeline (200 m long) passes through icy waters of a lake at . Measurements indicate that the surface temperature of the pipe is very nearly . Disregarding the thermal resistance of the pipe material, determine:
a. The temperature of the oil when the pipe leaves the lake;
b. The rate of heat transfer from the oil.
Properties of oil (@ ): = 888 ; k = 0.145 ; = 901 × ; = 1880 .
Worked solution
Data
| Quantity | Symbol | Value |
|---|---|---|
| Cold-section diameter and length | ||
| Mean speed | ||
| Inlet and wall temperatures | ||
| Density | ||
| Conductivity | ||
| Kinematic viscosity | ||
| Specific heat |
Assumptions
Assume steady hydrodynamically developed flow at the start of the cold section, a uniform inlet bulk temperature, constant properties and negligible viscous heating and axial conduction. Neglect pipe-wall resistance, so the inner wall is also isothermal at . The thermal boundary layer starts at the lake entrance. Check and .
Calculations
For laminar flow, estimate the thermal entry length with
Use the length-average laminar entrance correlation and integrated bulk balance for constant wall temperature:
The correlation models thermal development with a developed velocity profile; ignore wall-to-bulk viscosity corrections under the stated constant-property assumption. Do not substitute the fully developed value prematurely.
The oil velocity profile is laminar but its thermal boundary layer is still developing.
The supplied properties give , and , far longer than the cold section.
The large Prandtl number explains the long thermal entry region.
Equation Eq. 2 gives , and .
The mass flow rate is
The dimensionless exponent compares the wall conductance with the heat-capacity flow rate:
The exponential bulk balance then gives
The oil cools only 0.286 degrees because the heat-capacity flow rate is large.
This positive heat-loss convention is the magnitude of the negative heat input to the oil.
Retaining intermediate precision avoids the handwritten source’s rounded outlet temperature changing the reported duty to about 68.4 kW.
Answer
The oil exits at and loses over the cold section. The unrounded energy balance uses a bulk temperature drop of 0.286 K. The flow is laminar but thermally developing.
3 Water pipe in moving or stagnant air
Section titled “3 Water pipe in moving or stagnant air”Convection resistances per unit length
Section titled “Convection resistances per unit length”A thick-walled steel pipe (k = 60 ) carrying hot water is cooled externally by a cross-flow airstream at a velocity of 20 m/s and a temperature of . The inner and outer diameters of the pipe are 20 mm and 25 mm, respectively. At a certain location along the pipe, the mean temperature of the water is . Assuming the flow inside the tube is fully developed with a Reynolds number of 20,000, find the heat transfer rate to the air stream per unit pipe length. What will be the heat transfer rate if the surrounding air is stagnant?
Worked solution
Data
| Quantity | Symbol | Value |
|---|---|---|
| Inside and outside diameters | ||
| Steel conductivity | ||
| Water and ambient air temperatures | ||
| Internal Reynolds number | ||
| Cross-flow speed |
The property approximations are
| Property | Water | Moving air | Stagnant air film |
|---|---|---|---|
| Conductivity , | |||
| Prandtl number | |||
| Kinematic viscosity , | Not needed |
Assumptions
- Steady radial wall conduction with negligible fouling and axial wall conduction.
- An isolated long horizontal pipe with radiation excluded.
- The local bulk water temperature is fixed in both air cases.
Water and moving-air values follow the source solution. The stagnant-air values approximate air at 325 K and stay fixed while the film temperature in is iterated. Use .
Calculations
For internal water use the source’s Colburn form; for cylinder cross-flow use the stated Zukauskas approximation with the surface-Prandtl correction set to one:
The outside correlation applies to and . This explicitly uses the source’s internal exponent rather than the Dittus-Boelter cooling exponent. Resistances per unit length have units :
For stagnant air, the horizontal-cylinder Churchill-Chu relation is
Use
within the range , and recover . Evaluate the properties at
The outer surface temperature must satisfy both
and
Solve iteratively.
The external air film controls most of the forced-convection resistance.
The internal calculation gives and .
Outside, is within the stated range, and .
Using Eq. 3 gives
The outer surface is
The handwritten resistance labels transpose the inner and outer coefficients; their sum and approximate 489.5 W per metre result are nevertheless consistent.
Here each resistance uses its correct coefficient and diameter.
For stagnant air, trial an outer surface temperature between 25 and 80 degrees and equate the conductive/internal flux to the natural-convection flux.
The converged values are
Both heat-rate calculations agree:
The natural-convection Rayleigh number lies within the specified range.
The final film is close to the supplied 325 K property approximation.
Stagnant air removes much less heat and leaves the wall closer to the water temperature.
Radiation was excluded, so this is a convection-only comparison.
Answer
The heat loss is approximately in moving air and in stagnant air. The latter is the convection-only result for the specified horizontal pipe.