Workshop 10: Transient mass diffusion
Attempt these problems before opening the worked solutions.
1 Carbon diffusion into steel
Section titled “1 Carbon diffusion into steel”Time for case hardening
Section titled “Time for case hardening”The surface of a mild steel component is commonly hardened by packing the component in a carbonaceous material in a furnace at a high temperature for a predetermined time. Consider such a component with a uniform initial carbon concentration of 0.15% by mass. The component is packed in a carbonaceous material and is placed in a high‐temperature furnace. The diffusion coefficient of carbon in steel at the furnace temperature is given to be 4.8 × , and the equilibrium concentration of carbon in the iron at the interface is determined from equilibrium data to be 1.2% by mass. Determine how long the component should be kept in the furnace for the mass concentration of carbon 0.5 mm below the surface to reach 1%.
Worked solution
Data
| Quantity | Symbol | Value |
|---|---|---|
| Initial, surface and target mass fractions | ||
| Target depth | ||
| Diffusivity at furnace temperature |
Assumptions
Assume constant diffusivity, no bulk motion or reaction inside each solid, uniform initial concentration and a maintained surface concentration. The surface condition changes at . For constant density, carbon mass fraction obeys the same diffusion equation as concentration.
Calculations
Define the normalised concentration
Use the same ratio with mass fraction replacing in problem 1. The error function is
For interpolation, and . A calculator with an inverse error function can also be used.
Treat the solid as a semi-infinite medium with a planar surface at , where increases into the steel. Other surfaces are far beyond the diffusion penetration depth during the treatment. Assume no external transport resistance and constant steel density. Use fractions 0.0015, 0.012 and 0.010, or use percentages consistently. The semi-infinite solution is
The steel treatment time follows from the inverse error function at the specified depth.
The required fraction of the surface concentration change is
Hence Eq. 2 gives , where
Inversion gives .
Using ,
Interpolation of the supplied table gives about .
The source’s rounded gives about .
The characteristic penetration distance must be small relative to the component dimensions for this planar semi-infinite model to apply.
The answer excludes furnace heating time.
Answer
The required diffusion time at furnace temperature is , approximately . Furnace warm-up time is additional.
2 Hydrogen leaving a sheet
Section titled “2 Hydrogen leaving a sheet”Centre concentration in a finite slab
Section titled “Centre concentration in a finite slab”A large sheet of material 40 mm thick contains dissolved hydrogen at a uniform concentration of 3 . The sheet is exposed to a fluid stream, causing the concentration of the dissolved hydrogen to be reduced suddenly to zero at both surfaces. This surface condition is maintained constant thereafter. If the mass diffusivity of hydrogen is 9 × , how much time is required to bring the density of dissolved hydrogen to 1.2 at the centre of the sheet?
Worked solution
Data
| Quantity | Symbol | Value |
|---|---|---|
| Sheet thickness and half-thickness | ||
| Initial molar concentration | ||
| Target centre mass concentration | ||
| Surface concentration | ||
| Diffusivity | ||
| Molecular hydrogen molar mass |
The worked solution uses molecular hydrogen molar mass .
Assumptions
Assume one-dimensional diffusion normal to the faces, negligible edge effects and no external transport resistance. Set at the centre, with faces at and half-thickness . Define .
Calculations
The exact centre concentration ratio is
For , use the first-term approximation
Use Eq. 1 with . Convert the target mass concentration to molar concentration before forming the ratio. Check that the calculated is consistent with the approximation.
The sheet target is one fifth of its initial hydrogen concentration after unit conversion.
Convert the centre target to
Then
Solving Eq. 3 gives
The time uses the half-thickness, not the total thickness:
Since , the first-term approximation is appropriate.
The next term at this time is about in , so retaining it does not change the reported time.
The source chart gives and .
Using the full 40 mm thickness in place of would overestimate time by a factor of four.
Answer
The centre reaches of molecular hydrogen after , or . The resulting Fourier number supports the first-term approximation.
3 Drug release from a bead
Section titled “3 Drug release from a bead”Drug release from a spherical bead
Section titled “Drug release from a spherical bead”Consider a small spherical bead (D = 0.1 cm) that initially contains 0.2 mmol/L of the drug griseofulvin (species A). Determine the time it will take for the concentration of griseofulvin to reach 10% of its initial value, if its diffusivity within the bead material is 1.5 × . Upon release from the bead, the drug is immediately consumed so that the surface concentration can be assumed to be zero.
Worked solution
Data
| Quantity | Symbol | Value |
|---|---|---|
| Diameter and radius | ||
| Initial concentration | ||
| Target centre concentration | ||
| Surface concentration | ||
| Diffusivity |
The source question does not specify the location of the target concentration. This worked solution uses the centre, following the supplied solution.
Assumptions
Assume spherical symmetry, a fixed bead radius , constant temperature and no reaction inside the bead. The centre has zero radial concentration gradient; the surface at has . Define .
Calculations
The exact centre concentration ratio is
For , use
Check the approximation after computing . Centre concentration differs from the volume-averaged concentration. This question uses the centre, matching the coordinator’s worked solution.
The bead centre reaches the specified fraction when its Fourier number is about 0.304.
The target is , giving .
Using Eq. 4 yields
Use
and .
Then
The Fourier number exceeds 0.2.
At this time the second term of the exact centre series is , so the first-term ratio is accurate to about 0.013%.
The exact series gives about .
The source rounds to 0.3 and obtains or 1.39 hours.
The diameter must first be halved.
Initial concentration cancels from the ratio because this constant-property diffusion model is linear.
Answer
The bead centre reaches ten percent of its initial concentration after approximately , or . This is a centre-concentration result, not a volume-average result.